SCU6x Controller Operator Lockout During Automatic Mode

In this video, we explore the features and safety measures of the web guide controller when set to automatic mode. Key highlights include the operator lockout during automatic mode of the controller, which automatically disables the tools icon and various parameters like the edge sensor, contrast, speed, and gain. We also examine the limitations imposed on the operator's control, such as the inability to change sensor orientation or switch sensors. The video explains why these restrictions are in place and how the guide point reset functions, emphasizing the importance of careful usage and the implementation of an accept button to prevent accidental changes.

00:00 Introduction to Automatic Mode
00:15 Operator Restrictions in Automatic Mode
01:03 Sensor and Button Limitations
01:36 Guide Point Adjustments
01:55 Safety Measures and Accept Button